About this item

  • <b>★Load cell display instrument has the advantages of strong anti-interference ability, powerful function, easy operation, strong versatility, small temperature drift and high linearity, and is suitable for other measurement occasions such as weighing and mechanical strength testing.</b>
  • <b>★Small size, engineers can carry it with them, support Micro Android interface for power supply, ★Built-in HX711 chip for easy on-site debugging, ★Send data regularly, or when the weight changes</b>
  • <b>★Temperature coefficient: ≤100ppm/℃, ★A/D conversion rate: 6.25~100Hz★Measurement signal range: ±19mV</b>
  • <b>★Comprehensive protection function: It has multiple protections such as anti-reverse connection, anti-overvoltage, instantaneous suppression, etc.</b>
  • <b>★Using temperature range: -40℃~+70℃; ★Storage temperature range: -60℃~+90℃</b>



Product Description

EC Buying HX711 Weight Sensor Module

HX711 Digital Load Cell Module

HX711 Digital Load Cell Module

HX711 Digital Load Cell Module

HX711 Digital Load Cell Module

HX711 Digital Load Cell Module

Overview

Load cell display instrument, used for various weighing display occasions. 24-bit A/D high-precision weight value, the module can transmit the weighing value under the condition of displaying the weight value simultaneously, the sensor analog signal can maintain communication with the host computer such asa computer or PLC, which fully meets the requirements of automatic control. Used for weighing indicator, process controller

Table, tensile testing machine, and suitable fanotherher weighing, mechanical stretest,s test and other measurement occasions.

HX711 Digital Load Cell Module

Features

1. Small size, engineers can carry it around, support Micro Android interface for power supply

2. Can be built-in HX711 chip for easy on-site debugging

3. The data is sent regularly, or when the weight changes

4. Measurement signal range: ±19mV

5. Temperature coefficient: ≤100ppm/℃

6. A/D conversion rate: 6.25~100Hz

7. Comprehensive protection functions: multiple protections such as anti-reverse connection, anti-overvoltage, instantaneusingression, etc.

8. Operating temperature range: -40℃~+70℃; Storage temperature range: -60℃~+90℃

HX711 Digital Load Cell Module

Function Description

It has the functions of analog-to-digital conversion, digital calibration, tare, zero setting, anti-sh,ake and so on.

Strong anti-interference ability, strong versatility, small temperature drift, high linearity

The characteristic parameters are stored non-volatilely, and the parameters are still saved after the power is turned off;

Display: 4 digital tubes (decimal point can be set, automatic displacement)

Keyboard: 4 keys

Power supply: 5VDC, all copper high-resistance socket 3.5-1.3, power cord power supply DC3.5mm

Size: 55×35×12 (L×W×D mm)

A/D module acquisition speed: 0-100 times/second optional (default 30)

Sensor quantity: 4 350Ω load cells

Wiring diagram

HX711 Digital Load Cell Module

Parameter Setting

HX711 Digital Load Cell Module

Application Diagram

HX711 Digital Load Cell Module
HX711 Digital Load Cell Module

Duane Hall
Reviewed in the United States on February 26, 2025
The module performed as advertised, but I had to request full documentation from the seller to get details on the setup procedures and options. However, they were very responsive - I had my download link within 24 hours. If the data had been readily available for download, I would have given 5 stars. Can definitely recommend this part and the seller.
Holt
Reviewed in the United States on September 17, 2024
Nice little unit, very versatile with the following options:Power:- Micro USB- .1" Header- Barrel PlugData:- Display- TTL serialWhat it doesn't have:- Unit conversions (or any units at all)- Data over USB - this won't work as a USB-based scale.It works with any resistor bridge load cell, with or without the HX711 instrumentation amp.(This covers just about all load cells out there)There isn't a weight limit with this, the weight limit is dependent on the load cell you are using.The data will also display accurately in the negative direction as well (i.e. pulling on a compression load cell)Whether this will damage the load cell depends on the load cell you have, but this unit will still work.I've attached a better description of the buttons since theirs are not very clear.Tap function is listed, then the press and hold function in parenthesis.To set this up:1. Connect load cell then power to the board2. Press and hold "(Settings)" to access parameters3. Set parameters as desired. Press "Up"/"Down" to change parameter value, Press "Enter" to save value Press "Left" to go to the next parameter.4. Press and Hold "(Settings)" to access parameters5. Remove force from load cell, then press and hold "(Calibrate 0)"6. Set the value to 0 or your "neutral" value7. Press "Enter" to save value8. Add a calibrated force to the load cell, then press and hold "(Calibrate Weight)"9. Set the value to the weight or force in whatever unit you are working in.10. Press "Enter" to save value11. Remove the weight/force, then Press and hold "(Tare)" to reset to 0 (or your "neutral" value)Note: Fully recalibrate if you swap load cells with a different capacity and/or mV/V rate, but you should only need to tare if you swap with an identical load cell.
Tim Kern
Reviewed in the United States on March 21, 2024
This unit hooked up to my load cell and 5V, and it gives me an output, but I cannot understand from the instructions how to use it with an Arduino or even how to calibrate it.It does pick up small changes, though -- it captures the squeeze from my hand on a 2000 kg load cell, and that's sensitive!I wish I knew how to USE it, either as a direct-reading device or with my Arduino. The included directions are written in English, but they are impossible to understand.
Customer
Reviewed in the United States on November 9, 2024
Works great once you figure it out
DancerB
Reviewed in the United States on February 3, 2023
The instructions supplied by customer D. Maciuca are very helpful - thank you! I also downloaded and used those supplied by the manufacturer. I still had a learning process to go through before successfully getting it to work for me. In my experience, contrary to what it appeared to me was suggested by the two sources of instruction I just mentioned, one could not simply enter the value of the weight used to set the "high" calibration point. I needed to enter the value (which I found by multiple set and check repetitions) that would result in the correct weight being displayed. This is logical, as the amplifier/display module will work with load cells that have different output scaling (2 millivolt/volt or 1.2 millivolt/volt, for example). You set the "low" calibration point with no force applied (enter "0"), then apply a force reasonably within the normal measurement range of the load cell used (I used a 100 kg load cell with 1.2 mV/V output to measure tension and used a 20 kg weight for calibration) and adjust the high point value until the module shows the value you want displayed for that amount of weight. I have it display in pounds and so set a value that would result in the display showing "44" when I had 44 lbs (20 kg) hanging from the load cell. I did not enter "44" - I did at first, but that resulted in something around "12" being displayed, so I then entered higher "high" calibration point values until the display did show "44". The relationship between differing amounts of force applied and the output of the load cell is essentially perfectly linear, so the amplifier/display module will then correctly measure any other weight within the normal operating range of the cell, including those greater than the one you used for the "high" calibration point. One other thing that I learned the hard way is that you cannot screw female eye bolts to the threaded studs on a miniature/canister (as opposed to s-type) load cell so far that they contact the cell itself at all without causing the measurement to be extremely erratic. I ended up using a low profile nut on each side of the load cell, screwing them toward the cell down the studs as far as I could without touching the cell itself and then tightening the eye bolts against the nuts. I had at first made the mistake of screwing the eyebolts down until they contacted the load cell, not realizing that they would create an unstable compression force on the cell and play havoc with any attempt at calibration.
robert
Reviewed in the United States on April 19, 2023
Havent figures it out yet. There are no instructions and the board is labeled in Chinese
kevin dohrmann
Reviewed in the United States on August 21, 2022
Product is perfect but no documentation at all
Kindle Customer
Reviewed in the United States on November 22, 2022
This looking like a great product. It is well made. But there are no instructions available anywhere (with it nor on the internet). The only thing available is a YouTube video in Chinese.I do not recommend!