  • This module uses 24 high precision A/D converter chip hx711, specially designed for the high precision electronic scale
  • The load sensor is a group of half-bridge strain gauge, there are 3 ways to use it.
  • Use one load sensor 50kg with an external resistor to form a full-bridge measurement, the range of a sensor range: 50kg. External resistance on the higher requirements.
  • Use two weight sensor 50kg to form a full-bridge measurement, measuring range for the sum of the two sensors: 50kgx2 = 100kg
  • Use four weight scale 50kg to form a full-bridge measurement, measuring range for the sum of four sensors: 50kgx4 = 200kg



1. Using a Single Load Cell 1x50kg by Adding 2 Resistors
-Connect outer wire(white and black) of load cell to E+ and E- outputs of hx711 module.
-Connect middle cable(red) of load cell to A+ input of hx711 module.
-Connect two 1k resistors to A- input of hx711 module. Then the other end of resistor to white and black wires.
-Connect GND of hx711 module to board GND, and VCC to board 5V pin.
-Connect DT and SCK of hx711 module to any digital IO pins of board.

2. Using Two Load Cells in a Singel Circuit 2x50kg (100kg)
-Connect opposite sides of outer wires(white and black) of two load cells.
-Connect outer wire pairs to E+ and E- output of hx711 module.
-Connect middle wire(red) of load cell to A+ and A- inputs of hx711 module.
-Connect GND of hx711 module to board GND, and VCC to board 5V pin.
-Connect DT and SCK of hx711 module to any digital IO pins of board.

3. Using 4 Load Cells in a Single circuit 4x50kg (200kg)
-Form a loop by linking same color outer wires(white and black) of the four load cells.
-Connect middle cable(red) of one of the diagonals to the E+ and E- outputs of the HX711 module.
-Connect the other diagonal to the A+ and A- inputs of the HX711 module.
-Connect GND and hx711 module to board GND, and VCC to board 5V pin.
-Connect DT and SCK of hx711 module to any digital IO pins of board.

Package Included:
8 x 50kg Half-bridge Load Cell
2 x HX711 AD Weight Module


mad_scientist
Reviewed in the United States on May 27, 2024
The 1st photo shows a board with "MH" stamped on it. The actual chips they sent do not. They are different and look like the ones shown in photo 3. The boards are physically different. There is a lead from the HX711 "rate" to GND which is supposed to set the rate at 10 SPS per the data sheet. The HM chips don't have this (maybe imbedded, not sure). Other than that, I'm not sure the all the exact differences in the board. All I know is that they don't work.I bought a single board and 4 gage package from a different seller. It had a HM printed on the board. When hooked up to an Arduino, everything works fine. The chips reads (as well as the system can anyways)Since this one worked for my project, I ordered 2 sets of 2 each from this seller (so I could have a total of 5). figured I'd save a few buck getting them 2 at a time. They do NOT work. I tried everything including writing a bit-banging sketch to verify that it just wasn't incompatible with the HX771 library I was using. They don't work. The program hangs up after the first (erroneous) reading. I've tried 3 different HX711 libraries. I tried physically cutting the "rate" lead on the board (even though this should be correct per the HX711 data sheet). Nothing. The 4 boards from this seller do not read. The one with the MH does fine. There's something wrong with these. I don't know exactly what, but there is something wrong.OK, so after pulling out my hair for more time than I wanted, I figured it outThese boards are not wired properly. There is a pin for AGND on the HX711 chip that needs a ground. it's right there in the diagrams they have attached. instead, they just wired it to "-E". There's enough voltage bleed to totally screw up the circuit. This is bad design and incorrect.There is a solution... wire a jumper from -E all the way over to Ground. That got them working again. reading seem normal now. Although you shouldn't have to rewire a faulty design.
N
Reviewed in the United States on May 26, 2024
I ran mine into a nodemcu.I found one of the amplifiers was dead but it may have been my fault, I initially hooked it into the 5v feed.I found a great tutorial on youtube that showed how to setup a whetstone bridge with the hx711 and that set me on the right path.The most challenging part which I didn't initially understand was to route out a board to set the sensors into so they were suspended properly in such a way to allow a reading. Initially I just hot glued them flat to a board and that doesn't work. I used a 1" forstener to make a 1/4" deep hole in a piece of plywood and then glued them in place. In the next iteration I'll go dig for 3d printed feet since I've seen reference above to that.
Amir H.
Reviewed in the United States on February 12, 2024
Load Cell Amplifier NOT working" HX711 not found" not find in programDo Not Buy
AJ
Reviewed in the United States on February 6, 2023
You have to continually tare the weight and even then it’s not very accurate and unstable
Ohio_Matt
Reviewed in the United States on August 21, 2022
My biggest complaint with this is that there isn't enough documentation I could find with examples for common platforms and specific wiring instructions. But once I finally found and processed what I needed to know, it seems to work pretty well with my Pi Pico board here. For anyone else struggling to get two of these wired up, wondering if there need resistors involved or if some leads should be connected to supply voltage / ground: STOP. Just stop all of that. It's much easier than that. This is what worked for me, to wire up two to one HX711:Connect the white wire of one unit to the black wire of the other - connect both to E+ inputConnect the other white / black wires together and connect those to E- inputConnect the red wires to A+ / A- inputsConnect HX711 "DT" and "SCK" to Pico/etc GPIO pins (does not need to be analog), connect power and ground.From micropython, install HX711 (with upip or just find and save the file to the device manually)from HX711 import hx711driver = HX711(d_out = {the GPIO pin# you connected "DT" to}, pd_sck={the GPIO pin# you connected "SCK" to})driver.read()-> 45321and that's it. You'll have to calibrate it to an implementation specific minimum / maximum value within your code, how you actually mount it and what weight it holds without any load all change the specifics too much for a generalized solutionGood luck!I'm not sure if it matters which one goes to which (e+ versus e-, a+ versus a-), my setup here has worked like that with the first selection, I suspect it works either way.
Boiapple
Reviewed in the United States on May 16, 2022
If you want to play around with a sensor and just have fun is okay, but if it's for something important, get something else.
RC
Reviewed in the United States on March 27, 2022
Didn't have any surprises using this but i was a little dissapointed with how thin the wire for this was. Probably not even exaggerating when I say there's about 5 strands of wire inside. Makes it super hard to work with but it worked out.
fUNWiThTyPiNg
Reviewed in the United States on January 1, 2022
I had written a detailed review, but Amaz0n deleted it because it points to URLs that are not Amazon, but Github. Yeah, this company feels threatened by github. I pointed to a place where you could get plans for 3d printing feet. Also,to yaml scripts that allowed you to nicely set up these sensors on ESPHome. But that was all deleted. So, I regret buying them here and not from a less evil company.But that is not the fault of the seller. I created two identical setups. One worked, and one did not. Debugging shows that (at least) one of the load cells does not work. I wish that there were an easy way to test each of them.
Bruce M
Reviewed in Canada on April 19, 2022
Sensors not very responsive overall no easy to calibrate. Resistance not equal on all units