Voltage Monitor Module, A30-U1 30A DC 99.9V Voltage Detection Control Relay with Delay Battery Charge Discharge Timer with Overvoltage Undervoltage Control

Free shipping on orders over $29.99

$22.99

$ 11 .99 $11.99

In Stock

About this item

  • Separated Voltage: The measurement voltage is separated from the working voltage. The working voltage is DC 6V-80V while measuring voltage is DC 0-99.9V.
  • Free Setting: The voltage monitor module can flexibly set detection upper and lower limit voltage values and set triggering conditions.
  • Protective: It can realize functions such as voltage detection, overvoltage and undervoltage control, voltage alarm switch controller etc.
  • Delay Function: With delay function, the delay time is 1~9 minutes or keep ON (adjustable).
  • Guarantee: Any questions or concerns, please feel free to contact us so we can do our best to solve it. We will strive to provide the highest quality service for you.



Product Description

DC 99.9V Voltage Monitor Module with Delay

 Voltage Monitor Module

Features:

1.Separated measured voltage and working voltage

2.Wide voltage monitoring range 0.1V-99.9V

3.30A high current relay control

4.Support voltage calibration

5.Real-time voltage monitoring

6.Parameter power-off save

Voltage Detection Control Relay

Parameters:

1.Product name:A30-U1 DC 99.9V Voltage Monitor Module with Delay

2.Work voltage:DC 6V-80V

3.Measured voltage:DC 0-99.9V

4.Display voltage:DC 0-99.9V

5.Voltage calibration value:-0.5V~0.5V

6.Delay time:1~9minute or keen ON(adjustable)

7.Work current:4mA~58mA(at 24V)

8.Output type:Relay switch output(No output voltage!!!)

9.Load(Max):DC30V/30A or AC250V/30A

10.Work Temperature:-25℃~85℃

11.Work Humidity:5%~95%RH

12.Size:78*53*30mm

 Voltage Detection Module

DC Voltage Monitor Relay

DC Voltage Monitor Relay

DC Voltage Monitor Relay

Set Methods:

1.Screen display Current Measured Voltage Value automatically after power ON.

2.Press SET button enter into set mode and the first bit will keep flashing. The first parameter set is the Upper Limit Voltage Value.

3.Press ENTER button to set first bit value. Its set range is 0~9 as your needs.

4.Press SET button again to switch select the next bit and press ENTER button to change value.

5.Press SET button at 3rd time to switch select the last bit and press ENTER button to change value.

6.Then then first parameter ‘Upper Limit Voltage Value’ has been set.

7.Press SET button at 4th time to set next parameter the Lower Limit Voltage Value in the same methods. Note: its value needs less than the Upper Limit Voltage Value.

8.The third parameter is to set the Voltage Verification Value. Its set range is -0.5V~0.5V.

9.The 4th parameter is to set the Display Screen Automatically Turns OFF Remaining Time Value. Its set range is d-0 ~ d-9 which means after 1~9minute, the screen will turn OFF. Note: d-0 means the screen will keen ON all the time.

10.The 5th parameter is to set the Relay Triggering Status ‘ON H’ or ‘ON L’.

10.1.‘ON H’ : Relay output will turn ON if the Current Measured Voltage Value is more than the Upper Limit Voltage Value. Relay output will turn OFF if the Current Measured Voltage Value is less than the Lower Limit Voltage Value. It can be applied to battery discharging mode.

10.2.‘ON L’ : Relay output will turn ON if the Current Measured Voltage Value is less than the Lower Limit Voltage Value. Relay output will turn OFF if the Current Measured Voltage Value is more than the Upper Limit Voltage Value.It can be applied to battery charging mode.

11.Automatically enter detection status after set parameters and screen stop flashing.

12.At normal monitoring status, screen can display time for relay keep ON status in minute after press ENTER button. Stop timing when relay turn OFF. Restart timing if relay turn ON again. Keep press ENTER button about 3second can clear time.

DC Voltage Monitor Relay

Zeus
Reviewed in Italy on January 9, 2025
Fa il lavoro suo egregiamente, di facile installazione e configurazione! Consiglio
amendola antonio
Reviewed in Italy on August 19, 2024
Lo strumento non è dotato di istruzioni, pertanto non utilizzabile
christopher mundwyler
Reviewed in the United States on January 8, 2024
So this worked great mostly it started my device worked great until put to its potential then the light stayed on but no power the relay must have done
Dave-by-the-Beach
Reviewed in the United States on December 29, 2023
The feature they mention is that the working voltage for this device is separate from the measured voltage for triggering. That's nice, but nowhere nearly as nice as having relay contacts completely separate from both. With simpler controllers, the charging voltage is dumped in with the working and measured voltage, and higher voltage from a solar panel will boost the local voltage and create false triggering. You can set triggers higher on those to compensate, but the right way to fix it is to separate the relay contacts from all of that. This device is easy to configure and works splendidly as a charge controller, solar or otherwise.