Your cart is empty.Rated for continuous operating currents up to 10 amps @ 250VAC (15 amps @ 120VAC, 5 amps @ 24VDC), is the industry standard for over-temperature protection.
Steve F.
Reviewed in the United States on May 11, 2024
Works as good as the ones you buy in the pool store and are 1/3 the price.
Johnny the Sawyer
Reviewed in the United States on January 31, 2024
These fuses are one time overheat (flame rollout safety switches) or fuses. If your gas furnace blows (burns out) this swich/fuse, there typically is some issue with forced air (fan on) pushing flame out of heat exchanger onto thermal fuse (metallic part) due to a cracked cell. Many times a crack or separation allows the flame to forcefully push back out of the defective heat exchanger cell (rollout) onto itself when the blower fan comes on. They are one and done. No reset safety switches (fuses). Also, they typically don't just go bad bc they're old. I've worked on 20-30 year old systems with original safties. Replaced the heat exchanger and blown safety and left the other old one without issue. Additionally, installing a 152*c (@ 306*f) versus 167*c 333*f) is @ 9* c (27*f) is moot. A typical blue flame traveling into a heat exchanger cell can get up to over 3600*f. Any flame rollout will burn out (blow) a 260*c (500* f) safety switch/ fuse.24+ years HVAC, Electrical, Mechanical & Construction
Dave Robb
Reviewed in the United States on August 19, 2023
Fuse works fine, but mailed with no screws .
Kwatson
Reviewed in the United States on May 26, 2022
The media could not be loaded.
Customer
Reviewed in the United States on August 12, 2021
I started up my Raypak pool heater hoping to warm my pool up when halfway thru the fuse failed. The computer told me it was the fuse so I googled the part and quickly found it on Amazon. I decided to buy 5 because these fuses always break down and I don’t want to be left in cold water again. It does it’s job just like the original. Very nice and good price too.
Mona
Reviewed in the United States on November 2, 2021
Listed item for 156 C fuse and mailed the one for 167C. You can burn your unit using this fuse.
Dano
Reviewed in Canada on October 27, 2021
liked the price on these fuses.. very cheap.. same as what was in my pool heater.
M. Twain
Reviewed in the United States on September 23, 2020
Got 5 because if one or two goes out when its -20F it will cost a lot more to call in a person. Last winter I had some insulation fall and burn 2 out. I am ready for unforseen things now.
KC
Reviewed in the United States on September 18, 2020
These are the read deal. Fits great.