Shopping Cart

Your cart is empty.

Your cart is empty.

M12 Capacitive Proximity Sensor Switch Non-Shield Type LJC12A3-5-Z/BX Detector 1-5mm 10-30VDC 200mA NPN Normally Open(NO) 3 Wires

Free shipping on orders over $29.99

$12.99

$ 5 .99 $5.99

In Stock

About this item

  • Mounting Hole Diameter: 12mm
  • Detecting Distance: 5mm±10%; Set distance: 0-4mm
  • Output Type: NPN Normally Open(NO); Non-Shield Type
  • Current Output: 200mA; Working Voltage: 10-30VDC
  • Detect Object: Can detect any dielectric


  • Detection Object:Can detect any dielectric.
  • Delay Distance:10% below of the detection distance.
  • Supply Voltage:DC10-30V Impulse (p-p)10% below.
  • Comsuption Current:13mA below.
  • Control Output: 200mA below.
  • Loop Protection :reversal connection protection,surge absorption,load short-circuit protection.
  • Ambient Temperature & Humidity:During operation , storage : individually-30~+65℃(no freeze ,no drew ) ,During operation,storage:individually 35-95%RH.
  • Insulation Impedance :50MΩ above ( DC500 megameter ) between charging part and shell.
  • Withstand Voltage : AC1000V 50/60Hz 1 min. between charging part and shell.
  • Temperature Influence : Temperature range-30~+65℃,at + 23℃,± 15% detection distance, Temperature range-25~+60℃,at +23℃,±10% detection distance.
  • Voltage influence : Inside ±I5% rated supply voltage range,at rated supply voltage value ,inside ± 10 % detection distance.
  • Protection structure: IP67(IEC specification)

Downisser
Reviewed in the United Kingdom on September 26, 2023
But not the length
Mazzolini Matteo
Reviewed in Italy on January 8, 2022
The media could not be loaded.
Cliente
Reviewed in Spain on September 14, 2020
Lo utilizo para realizar el Auto Bed Leveling de mi impresora 3d (una Anet A6). Una vez configurado (lo cuesta un poco, aunque finalmente te das cuenta de lo lógico que es todo) funciona a las mil maravillas. Se acabó nivelar la cama a mano cada vez que quieres imprimir, con lo que ello conlleva de tiempo y lo engorroso que es). Ahora, una vez realizados los ajustes iniciales necesarios tras instalar el sensor, la impresora se encarga ella sola de realizar el auto nivelado con cada impresión. El sensor funciona perfectamente y, de momento, no me ha dado ningún falso positivo. Es muy preciso y constante en todas las mediciones. Un compra estupenda.
bdc
Reviewed in France on January 29, 2018
un peu surpris au début car habitué a avoir des capacitifs avec une protection orange et pas bleue (comme les inductifs).Montage facile sur Prusa I3 rework 1.5 en remplacement d'un inductif.Fonctionne parfaitement et la vis de réglage est tres utile. pensez a la bloquer une fois le parametrage fini avec une petite goutte de colle chaude.
Steffen T.
Reviewed in Germany on April 6, 2018
Hätte ihn beinahe zurück geschickt.Im Lieferzustand war der Detektionsabstand ca. 8mm. Die Reproduzierbarkeit der Erkennung ließ sehr zu wünschen übrig. +/- 0,5mm, für einen 3D Drucker völlig unbrauchbar!Ok, noch mal ein wenig informiert und die Empfindlichkeit etwas zurück geschraubt. Der Sensor reagiert jetzt ab ca. 4mm. Reproduzierbarkeit ist ganz gut für ein kapazitives System. Habe mit Marlin eine Testreihe mit 50 Punkten aufgenommen. Hier die Ergebnisse für Leute die sich auskennen.M48 Z-Probe Repeatability TestPositioning the probe...Bed X: 99.000 Y: 150.000 Z: -0.0031 of 50: z: 0.003 mean: 0.0025 sigma: 0.000000 min: 0.003 max: 0.003 range: 0.0002 of 50: z: 0.010 mean: 0.0062 sigma: 0.003750 min: 0.003 max: 0.010 range: 0.0073 of 50: z: 0.010 mean: 0.0075 sigma: 0.003536 min: 0.003 max: 0.010 range: 0.0074 of 50: z: 0.007 mean: 0.0075 sigma: 0.003062 min: 0.003 max: 0.010 range: 0.0075 of 50: z: 0.000 mean: 0.0060 sigma: 0.004062 min: 0.000 max: 0.010 range: 0.0106 of 50: z: -0.003 mean: 0.0046 sigma: 0.004877 min: -0.003 max: 0.010 range: 0.0127 of 50: z: 0.005 mean: 0.0046 sigma: 0.004518 min: -0.003 max: 0.010 range: 0.0128 of 50: z: 0.012 mean: 0.0056 sigma: 0.004961 min: -0.003 max: 0.012 range: 0.0159 of 50: z: 0.025 mean: 0.0078 sigma: 0.007678 min: -0.003 max: 0.025 range: 0.02710 of 50: z: 0.005 mean: 0.0075 sigma: 0.007331 min: -0.003 max: 0.025 range: 0.02711 of 50: z: 0.017 mean: 0.0084 sigma: 0.007558 min: -0.003 max: 0.025 range: 0.02712 of 50: z: 0.007 mean: 0.0083 sigma: 0.007241 min: -0.003 max: 0.025 range: 0.02713 of 50: z: 0.007 mean: 0.0083 sigma: 0.006960 min: -0.003 max: 0.025 range: 0.02714 of 50: z: -0.012 mean: 0.0068 sigma: 0.008579 min: -0.012 max: 0.025 range: 0.03715 of 50: z: 0.012 mean: 0.0072 sigma: 0.008410 min: -0.012 max: 0.025 range: 0.03716 of 50: z: 0.010 mean: 0.0073 sigma: 0.008171 min: -0.012 max: 0.025 range: 0.03717 of 50: z: 0.022 mean: 0.0082 sigma: 0.008693 min: -0.012 max: 0.025 range: 0.03718 of 50: z: 0.017 mean: 0.0088 sigma: 0.008710 min: -0.012 max: 0.025 range: 0.03719 of 50: z: 0.005 mean: 0.0086 sigma: 0.008519 min: -0.012 max: 0.025 range: 0.03720 of 50: z: 0.007 mean: 0.0085 sigma: 0.008307 min: -0.012 max: 0.025 range: 0.03721 of 50: z: -0.003 mean: 0.0080 sigma: 0.008438 min: -0.012 max: 0.025 range: 0.03722 of 50: z: 0.012 mean: 0.0082 sigma: 0.008298 min: -0.012 max: 0.025 range: 0.03723 of 50: z: 0.020 mean: 0.0087 sigma: 0.008466 min: -0.012 max: 0.025 range: 0.03724 of 50: z: 0.022 mean: 0.0093 sigma: 0.008734 min: -0.012 max: 0.025 range: 0.03725 of 50: z: 0.003 mean: 0.0090 sigma: 0.008660 min: -0.012 max: 0.025 range: 0.03726 of 50: z: 0.022 mean: 0.0095 sigma: 0.008880 min: -0.012 max: 0.025 range: 0.03727 of 50: z: 0.007 mean: 0.0094 sigma: 0.008722 min: -0.012 max: 0.025 range: 0.03728 of 50: z: 0.012 mean: 0.0096 sigma: 0.008584 min: -0.012 max: 0.025 range: 0.03729 of 50: z: 0.030 mean: 0.0103 sigma: 0.009223 min: -0.012 max: 0.030 range: 0.04230 of 50: z: 0.022 mean: 0.0107 sigma: 0.009330 min: -0.012 max: 0.030 range: 0.04231 of 50: z: 0.012 mean: 0.0107 sigma: 0.009184 min: -0.012 max: 0.030 range: 0.04232 of 50: z: 0.022 mean: 0.0111 sigma: 0.009269 min: -0.012 max: 0.030 range: 0.04233 of 50: z: 0.020 mean: 0.0114 sigma: 0.009254 min: -0.012 max: 0.030 range: 0.04234 of 50: z: 0.015 mean: 0.0115 sigma: 0.009138 min: -0.012 max: 0.030 range: 0.04235 of 50: z: 0.015 mean: 0.0116 sigma: 0.009025 min: -0.012 max: 0.030 range: 0.04236 of 50: z: 0.020 mean: 0.0118 sigma: 0.009006 min: -0.012 max: 0.030 range: 0.04237 of 50: z: 0.000 mean: 0.0115 sigma: 0.009088 min: -0.012 max: 0.030 range: 0.04238 of 50: z: 0.015 mean: 0.0116 sigma: 0.008985 min: -0.012 max: 0.030 range: 0.04239 of 50: z: 0.022 mean: 0.0119 sigma: 0.009036 min: -0.012 max: 0.030 range: 0.04240 of 50: z: 0.017 mean: 0.0120 sigma: 0.008965 min: -0.012 max: 0.030 range: 0.04241 of 50: z: 0.005 mean: 0.0118 sigma: 0.008921 min: -0.012 max: 0.030 range: 0.04242 of 50: z: 0.022 mean: 0.0121 sigma: 0.008963 min: -0.012 max: 0.030 range: 0.04243 of 50: z: 0.025 mean: 0.0124 sigma: 0.009069 min: -0.012 max: 0.030 range: 0.04244 of 50: z: 0.022 mean: 0.0126 sigma: 0.009092 min: -0.012 max: 0.030 range: 0.04245 of 50: z: 0.007 mean: 0.0125 sigma: 0.009022 min: -0.012 max: 0.030 range: 0.04246 of 50: z: 0.020 mean: 0.0127 sigma: 0.008990 min: -0.012 max: 0.030 range: 0.04247 of 50: z: -0.005 mean: 0.0123 sigma: 0.009252 min: -0.012 max: 0.030 range: 0.04248 of 50: z: 0.012 mean: 0.0123 sigma: 0.009155 min: -0.012 max: 0.030 range: 0.04249 of 50: z: 0.012 mean: 0.0123 sigma: 0.009061 min: -0.012 max: 0.030 range: 0.04250 of 50: z: 0.027 mean: 0.0126 sigma: 0.009219 min: -0.012 max: 0.030 range: 0.042Finished!Mean: 0.012600 Min: -0.012 Max: 0.030 Range: 0.042Standard Deviation: 0.009219Denke mal, das ist für den Sensor mehr als OK! Wenn das auch Langzeit stabil ist (wird sich zeigen), volle Kaufempfehlung!Info für die, die wirklich wissen, was da oben steht, Trapezgewindespindel, 1,5mm Steigung, Stepper 200 Steps/Umdrehung im 1/16-tel Microschritt. Die Spindel dürfte keine Ungenauigkeiten hervorrufen aber der Microstep Betrieb ist nie 100%-ig genau.Ach ja, Lieferzeit war auch Super!Besten Dank!