- Home
-
All Categories
- Sports & Outdoors
- Baby
- Industrial & Scientific
- Arts, Crafts & Sewing
- Musical Instruments
- Tools & Home Improvement
- Office Products
- Kitchen & Dining
- Computers & Accessories
- Automotive
- Clothing, Shoes & Jewelry
- Pet Supplies
- Patio, Lawn & Garden
- Home & Kitchen
- Toys & Games
- Video Games
- Health & Household
- Electronics
- Camera & Photo Products
- Cell Phones & Accessories
- Beauty & Personal Care
- Sports Collectibles
- Appliances
- Grocery & Gourmet Food
- Software
- Payment
- About Us
- FAQ
- Privacy Notice
- Shipping & Returns
- Contact Us
Your cart is empty.
Your cart is empty.- Home /
- Industrial & Scientific
- Cutting Tools
- Industrial Electrical
- Adhesives, Sealants & Lubricants
- Hydraulics, Pneumatics & Plumbing
- Occupational Health & Safety Products
- Raw Materials
- Commercial Door Products
- Power Transmission Products
- Fasteners
- Science Education
- Test, Measure & Inspect
- Filtration
- Professional Dental Supplies
- Food Service Equipment & Supplies
- Material Handling Products
- Professional Medical Supplies
- Lab & Scientific Products
- Industrial Hardware
- Packaging & Shipping Supplies
- Digital Signage
- Abrasive & Finishing Products
- Janitorial & Sanitation Supplies
- Retail Store Fixtures & Equipment
- Additive Manufacturing Products
- Robotics
- Power & Hand Tools
/
- Hydraulics, Pneumatics & Plumbing /
- Pumps & Accessories /
- Peristaltic Metering Pumps
Product Description
UIP WIFI E-S183

- Includes a 4.3 inch touch screen for easy operation.
- Rich control methods, including touch screen, foot switch, RS485 and voltage analog operation.
- Supports flow rate calibration.
- Supports continuous mode and quantitative mode operation.
- Supports power-down parameter saving.
- Back interface adopts quick-connect terminals, easy to connect.
- Support remote firmware upgrade.
Basic Parameters
Working voltage | AC: 100~240V |
Flow rate range | 0.5~1500ml/min |
Power | <50W |
Motor type | Stepper motor |
Pump head | KK1800 |
Speed range | 0.1~350rpm |
Dimension | 324*164*219mm(L*W*H) |
Weight | 3145g |
Reference noise value | ≤65dB (horizontal distance between test product and noise meter is 0.5 meters) |
Working mode | Continuous mode, ration mode, remote control |
Control mode | Touch screen, foot switch, 0~5/10V analog, RS485 communication |
Working environment | Temperature 0℃~60℃, relative humidity<80%RH |
Storage environment | Temperature -20℃~80℃, relative humidity 10%~90% (non-condensing) |

1. Continuous mode:
Applied to non-fixed amount of added occasions, the pump running and stopping the user through the touch screen or foot switch to trigger; in the title bar, select "switch mode" to enter the mode selection interface, click on "continuous" to enter the continuous mode working interface, click on the start, the pump will run continuously until the stop button is clicked. After clicking start, the pump will run continuously until the stop button is clicked;
2. Ration Mode:
Suitable for filling occasions, the pump runs for a dosage, and then stops automatically, the user can manually trigger the start, you can also set the number of cycles, so that the pump runs cyclically; Select "Switch Mode" in the title bar to enter the mode selection interface, click "Ration" to enter the dispensing mode working interface;In the ration mode, there are two working modes, namely, semi-automatic working mode and full-automatic working mode;
Semi-automatic working mode: after volume setting, click the start button to start running, the volume (flow) displayed on the screen starts counting down, when the count value changes from the set value to 0, the pump stops working, click start again, the pump runs again in the above way;
Full-automatic working mode: set the number of times of operation, volume, pause time, click to start running, the volume displayed in the screen (flow) began to count down, when the count value from the set value to 0, the pump stops working, at the same time the middle of the screen began to count down the pause time, when counting down to 0, the pump automatically restarted the work of the pump for each run, the number of times h plus 1, when the pump cycle through the set number of times of operation, the pump stops running, waiting for a second time, waiting for a second time, the pump runs again in the above way. When the pump cycles through the set number of times, the pump stops running and waits for clicking start to begin the next cycle;(Note: Before the pump starts to run, the pump tube must first be filled with liquid and drained of air to ensure the accuracy of the pump;)
3. Remote mode: This mode allows the user to control the running status of the pump by means of non-touch screen, such as RS485, 0~5V/10V Analog, applicable to supporting the use of user systems; in the title bar, select "switch mode" to enter the mode selection interface, click "remote" to enter the remote control interface. program" to enter the remote control interface;
4. Analog control: In the application scenario that requires the use of analog control devices, you can choose analog control to achieve motor speed control, the value of the analog determines the running speed of the motor; analog has two ways: current or voltage, of which the current mode can be customized according to the demand; according to the definition of analog interface to connect the analog communication line (the following figure), select the corresponding analog in the remote control interface, click to enter the corresponding analog control interface.

$56.66 $56.66
$ 29 .99 $29.99
$325.00 $325.00
$ 99 .00 $99.00
$19.99 $19.99
$ 9 .99 $9.99
$78.86 $78.86
$ 31 .99 $31.99