Your cart is empty.
Your cart is empty.Charles
Reviewed in the United States on January 13, 2025
Mounted this behind my Frame TV. Works great, but the cover sticks out preventing me from using it since the TV goes flush against the wall.
TopDog82
Reviewed in the United States on February 8, 2024
I forgot to make note of which EIA wiring standard the CAT-6 module was setup for before ordering. I got an unpleasant surprise when I unpacked the panel and started working on terminating my cables, only then discovering it was setup for EIA-568A. Unfortunately, I'd already terminated by drops as 568B, so I had to go back and re-terminate the drops. Fortunately, my network is small, so I didn't have to do too many.Otherwise the enclosure is great. I found there was plenty of room inside it for my little 5-port switch.
Marcus
Reviewed in the United States on January 13, 2024
We installed it behind our living room TV, and it’s flush.
Rod Swartz
Reviewed in the United States on March 18, 2022
Updating an old house and used this panel to centralize all those cables run around the exterior of the house...now I can pull them all into the attic and run them into this box. We've ditched land-lines so we won't be using the phone portion. Also will be using this box to run data lines throughout the house for greater data speeds. Clean install in an empty wall cavity with a couple of drywall screws and completely customizable.
Judi
Reviewed in the United States on March 22, 2021
Liked
Thomas Franklin
Reviewed in the United States on April 18, 2018
Not much to say, it work as it should and was easy to install. Can't beat that.
Isaac P.
Reviewed in the United States on May 28, 2017
Everything pretty well packaged. All components were delivered. Works as advertised, great for medium size home. Don't look for something bigger and worthless.
jr
Reviewed in the United States on October 6, 2017
This is a perfect enclosure for a 3-4 bedroom home. There is enough working space and the punch outs are ample. The AC outlet punch out needs a tool / cutter to break it free, don’t try to pop it free by pushing on it. Also the holes on the AC outlet are a little off and need to be drilled a bit to fit the jbox. The punch down blocks for the telephone and data are decent... they have a bit of flex to them so punching on the ends can be a bit tricky.My cable provider made me swap out the splitter because it wasn’t “the right megahertz”. I didn’t argue with him... even though the ICC 5 way is OVER rated for cable TV.The documentation is also fairly decent. The documentation states modules are 568A coded and it checked out with the continuity tester. My only gripe with the paperwork is that some of the text is so small you can’t read it.Overall, very pleased. Good value for the money. Structured wiring enclosures and modules can get pricy ... this one makes the right compromises for the value.
Recommended Products