Shopping Cart

Your cart is empty.

Your cart is empty.

DOMETIC 3312022 Duo Therm Electronic Board

Free shipping on orders over $29.99

$176.00

$ 83 .99 $83.99

In Stock
  • Product Type :Auto Accessory
  • Package Dimensions :6.5 Cm L X13.0 Cm W X19.4 Cm H
  • Country Of Origin :China
  • Package Weight :10.5Lbs


Dometic Part #3312022000
Board Ccc2 Pcb
Package Quantity = 1


Michael Short
Reviewed in the United States on August 25, 2024
Circuit board was previously installed and was defective.
Cheri Cooke
Reviewed in the United States on March 30, 2022
Matched original part. Works as it should. Easy swap out of part
Frozenfingers
Reviewed in the United States on April 10, 2022
Did not work for my dometic a/c due to having a 5 button thermostat. It would have been very helpful and saved me this purchase had it been clearly identified for penguins with a 10 button thermostat in the description.
Lisa W
Reviewed in the United States on July 28, 2021
Worked to fix our A/C problem on the RV - right out of the box. I was skeptical, but once installed, the A/C came on & is now doing it's job keeping the RV cool. Fantastically quick shipping!
Jpsoulmate
Reviewed in the United States on November 10, 2021
Just the part I needed
Bob
Reviewed in the United States on October 14, 2021
A/C compressor and blower not coming on when in cool mode. You could turn fan on all three settings in fan mode(manually) The hour glass would just stay on when in cool mode. (No fan or noise)Replace board and fixed problem. Kinda difficult to replace if not used to this kinda repair.Testing the board I found:All the 4 small relays tested bad with meter.Coil side worked (400ohm)but load side contact was stuck or worn. No ohms when activated.
SSN604
Reviewed in the United States on December 16, 2020
I originally thought I had a bad board which is why this review is late. After looking at the schematic in detail I realized I had one lead out of place. Is you use this board the terminals are numbered on the board T4 etc. These numbers match the schematic in the A/C unit. The only difference I found was two wires said to be black were actually purple. Once I changed the lead the system has worked as it should. My symptoms prior to installing the new board were that the compressor would shut down but fan would keep running, compressor would not come back on. If I shut the unit down and turned it back on then the compressor would come back on until thermostat turned it off again. Seemed to me to be an obvious relay problem (usually fused contacts)